Fixed detection of gases & substances: hydrogen chloride (HCl)

Discover our selection of fixed devices and devices for the detection of gases and hazardous substances. Detector: hydrogen chloride (HCl), Acide chloridrique. Formulas: HCl. Dosi-tubes : 14D - 132D, Colorimetric tubes : 14R - 14R - 14M - 14M - 14M - 14L - 14L - 14L - 80 - 8HH
See its properties.


MIDAS

Gas detector for AsH3, B2H6, BCl3, BF3, Br2, C2H4O, Cl2, ClF3, ClO2, CO, COCl2, F2, GeH4, H2, H2S, H2Se, HBr, HCl, HCN, HF, HMDS, N2H4, NH3, NO, NO2, O2, O3, PH3, POCl3, Si2H6, SiCl4, SiHCl3, SO2, TEOS, TMB, TMP, WF6.

  • Smart sensor cartridge with calibration certificate and ready to use
  • The cartridge has an integrated on board “e-calibration”
  • Integrated sampling pump
  • Units are powered by 24 VDC
  • Transmitters provides 0-22 mA analog and Modbus/ TCP Ethernet as standard outputs
  • 3 integral relays for alarm 1, alarm 2 and fault

SATELLITE XT

Digital gas detection transmitter able to detect toxic gases : AsH3, B2H6, BBr3, BCl3, BF3, Br2, C2H4, C4F6, C5F8, CH3COOH, CH3F, ClF3, COCl2, 1,2-DCE, DMA, F2, GeH4, H2Se, HBr, HF, HMDS, MCF, MMH, NF3, O3, POCl3, SF6, Si2H6, SiCl4, SiF4, SiH2Cl2, SiH3Cl, SiHCl3, SiCl4SiH4, SiHCl3, TBA, TBP, TDMAT, TMB, TMP, UDMH, WF6

  • Digital display showing the measured value
  • 3 programmable alarm relays : 2 gas alarms and one fault alarm
  • 4-20 mA output
  • Intelligent Interchangeable sensors
  • Pyrolyzer module to detect C4F6, C5F8, CH3F, DCE 1.2, NF3 et SF6
  • To be used in unclassified areas
Further information on the fixed detector SATELLITE XT

Le bon fonctionnement des équipements de détection de gaz requiert obligatoirement une maintenance et un étalonnage périodique. Ces opérations deviennent bien souvent très coûteuses pour les gaz particulièrement toxiques ou rares (approvisionnement des gaz étalons, date de validité des bouteilles, etc...). Une solution pertinente et économique, les détecteurs gaz à cellules interchangeables : vous commandez la cellule gaz, vous la remplacez vous-même tous les ans (système plug and play embrochable) et l’appareil est étalonné ! (Stockage de la cellule : de 6 à 12 mois).

Le Satellite XT est un appareil de mesure de gaz spécialement conçu pour assurer la surveillance continue des concentrations de gaz dangereux. L’appareil est destiné à être relié à des systèmes d’alarme ou de commande classiques (0) 4 ... 20 mA. Le gaz cible et l’intervalle de mesure dépendent du type de capteur choisi. Le capteur est livré avec ses données propres, stockées dans sa mémoire interne. Lorsqu’un nouveau capteur est inséré, ces données sont chargées dans la mémoire interne de l’instrument.

En option, Le Satellite XT dispose de 3 relais unipolaires pour l’activation de dispositifs d’alarme externes. Lorsque la concentration réelle du gaz est supérieure aux seuils d’alarme, l’instrument active le relais d’alarme approprié et affiche un message correspondant. Un relais sera également activé si l’instrument tombe en panne.

Télécharger la fiche du produit


OLCT100

The OLCT100 range of fixed detectors is available in five versions in order to answer all kind of need. Each version has its own characteristics depending on the gas

  • Sensor : catalytic bead, infrared, electrochemical or semiconductor
  • Standard linear 4 to 20 mA output – supply voltage 15.5 to 32 VDC
  • ATEX certification (SIL2)
  • Large range of accessories
  • Dust and humidity resistant (IP66)
  • Epoxy-coated aluminium housing
Further information about the detector OLCT100

La grande diversité de technologie de cellule adaptable au détecteur de gaz fixe OLCT100 permet à cet appareil de détecter une très large gamme de gaz : les gaz explosifs peuvent être détecté à l'aide d'une cellule catalytique ou infrarouge, les gaz toxiques par le biais d'une cellule électrochimique, les fréons avec une cellule semi-conducteur et le dioxyde de carbone grâce à une cellule infrarouge.

 

Deux types de sorties sont disponibles pour cette gamme de détecteur de gaz fixe. La première est une sortie analogique 4-20 mA. Elle peut être utilisé dans la détection des gaz explosifs, toxiques, asphyxiants, mais également pour les solvants, les fréons ou encore le dioxyde de carbone (CO2). La seconde version, est un capteur sortie pont de Wheastone pour la détection des gaz explosifs (uniquement en 0-100% LIE).

 

De nombreux accessoires sont disponibles pour le détecteur de gaz OLCT100 pour augmenter le temps de réponse de la cellule ou installer ce dernier dans des conditions optimales.

 

Cinq versions de la gamme OLC/OLCT100 sont disponibles :

 

  • OLC100 : Capteur à sortie pont de Wheastone pour la détection des gaz explosifs (en 0-100% LIE uniquement)
  • OLCT 100 XP : Version antidéflagrante et muni d'une cellule catalytique, électrochimique ou semi-conducteur pour la détection des gaz explosifs, toxiques ou de l'oxygène.
  • OLCT 100 IS Version extrêmement fiable et possédant un capteur pour la détection des gaz toxiques ou de l'oxygène.
  • OLCT 100 XP IR Version antidéflagrante et équipée d'un capteur infrarouge pour la détection des gaz explosibles ou du CO2.
  • OLCT 100 XP HT Version antidéflagrante haute température pour la détection des gaz explosifs jusqu'à 200 °C environ.

 

Télécharger la fiche du produit


Détecteur ATEX série 3000

2 wire loop powered ATEX detector / transmitter (loop powered 4-20 mA connection) Rugged and low consumption detector able to detect CI2, ClO2, CO, ETO, F2, H2, H2S, HCl, HCN, HF, NH3, NO, NO2, O2, O3, SO2

  • 2 wire loop powered 4-20 mA connection
  • Large and intuitive LCD display : clear information
  • Dust and humidity resistant (IP66)? NEMA 4x
  • Epoxy painted aluminium alloy LM25 or stainless steel
  • Certification : ATEX, IEC Ex or UL
  • Many accessories for the mounting
Further information about the gas detector ATEX Série 3000