pentan-1-ol (C5H12O)
pentan-1-ol (C5H12O)
Common synonyms: Amyl alcohol, Pentan-1-ol (French), n-Pentanol (French)
Properties of pentan-1-ol (C5H12O):
- Reactivity: 1-pentanol can react violently with strong oxidizing agents and is flammable.
- Melting point: The melting point of 1-pentanol is approximately -78°C.
- Solubility: 1-pentanol is soluble in water in small quantities, but miscible in most organic solvents.
- Health risks: 1-pentanol may cause skin and eye irritation. Prolonged exposure or high concentrations may cause headaches, dizziness and nausea.
- Protection and prevention: It is recommended to handle 1-pentanol in a well-ventilated environment, to wear personal protective equipment such as gloves and goggles, and to store the substance in a cool, dry place away from heat sources and oxidizing agents.
| Formula | C5H12O |
| International name | pentan-1-ol |
| French name | 1-pentanol |
| CAS | 71-41-0 |
| EINECS | 201-368-7 |
| Filter | A |
| IP (eV) | 10,00 |
| Vapour density (air = 1) | 3,04 |
| Conversion (1 ppm =) | 3.6 mg/m3 |
| LIE | 1.2 % |
| LSE | 10 % |
| VLEP CT (15mn) | - |
| VLEP (8h) | 100 ppm |
| STEL (15 min.) | - |
| TWA (8h) | - |
Gas detectors for pentan-1-ol (C5H12O)
pentan-1-ol (C5H12O), both explosive and classified as a volatile organic compound (VOC), requires special attention. Although it can reach explosive concentrations, it is essential to prioritize its detection in ppm, as its toxicity is the primary hazard. For this purpose, detection with a PID cell is recommended, enabling accurate measurement of low pentan-1-ol (C5H12O) concentrations.
Ventis® Pro 5 Portable multi gas detector with PASS
Ventis® MX6 iBrid® multi gas detector (up to 6 gases)
Gas leak detectors - Catharometer GT Series
VOC detector with PID sensor Xam 8000
OLCT100 Fixed Gas Detector
OLCT80 Fixed gas detector
KwikSense PID VOC Detector
SearchPoint Optima Plus explosive gas detector
Gas mask for pentan-1-ol (C5H12O)
To protect yourself from pentan-1-ol (C5H12O), we recommend a type A mask (suitable for organic gases and vapors with a boiling point above 65°C) for short-term operations. For longer assignments, a more comfortable, assisted-ventilation device is recommended.
GVS Elipse FFP3 half mask with integrated filters
GVS Elipse Integra mask with safety glasses
X-plore 3300 Bi-filter half mask
X-plore 6300 Full face respirator
CleanSpace Pro Powered air purifying mask
Powered air purifying respirator Proflow 2
X-plore 8000 Powered air purifying device