GASFIND’S TERMS OF USE

By consulting www.gas-find.com (owned by GazDetect) the user agrees to have previously taken note, acknowledged and accepted these Terms of Use, including the liability clauses.

 

Field of use: the user consulting www.gas-find.com agrees to accept to the full extent to be bound by these Terms of Use, including the exclusive liability causes they contain. The User also agrees to have fully read and understood them, to be 18 of age or older, and able of discernment.

Read more...

Fixed detection of gases & substances: 2-methyl-2-pentene (C6H12)

Discover our selection of fixed devices and devices for the detection of gases and hazardous substances. Detector: 2-methyl-2-pentene (C6H12). Formulas: C6H12
See its properties.


OLCT100

The OLCT100 range of fixed detectors is available in five versions in order to answer all kind of need. Each version has its own characteristics depending on the gas

  • Sensor : catalytic bead, infrared, electrochemical or semiconductor
  • Standard linear 4 to 20 mA output – supply voltage 15.5 to 32 VDC
  • ATEX certification (SIL2)
  • Large range of accessories
  • Dust and humidity resistant (IP66)
  • Epoxy-coated aluminium housing
Further information about the detector OLCT100

La grande diversité de technologie de cellule adaptable au détecteur de gaz fixe OLCT100 permet à cet appareil de détecter une très large gamme de gaz : les gaz explosifs peuvent être détecté à l'aide d'une cellule catalytique ou infrarouge, les gaz toxiques par le biais d'une cellule électrochimique, les fréons avec une cellule semi-conducteur et le dioxyde de carbone grâce à une cellule infrarouge.

 

Deux types de sorties sont disponibles pour cette gamme de détecteur de gaz fixe. La première est une sortie analogique 4-20 mA. Elle peut être utilisé dans la détection des gaz explosifs, toxiques, asphyxiants, mais également pour les solvants, les fréons ou encore le dioxyde de carbone (CO2). La seconde version, est un capteur sortie pont de Wheastone pour la détection des gaz explosifs (uniquement en 0-100% LIE).

 

De nombreux accessoires sont disponibles pour le détecteur de gaz OLCT100 pour augmenter le temps de réponse de la cellule ou installer ce dernier dans des conditions optimales.

 

Cinq versions de la gamme OLC/OLCT100 sont disponibles :

 

  • OLC100 : Capteur à sortie pont de Wheastone pour la détection des gaz explosifs (en 0-100% LIE uniquement)
  • OLCT 100 XP : Version antidéflagrante et muni d'une cellule catalytique, électrochimique ou semi-conducteur pour la détection des gaz explosifs, toxiques ou de l'oxygène.
  • OLCT 100 IS Version extrêmement fiable et possédant un capteur pour la détection des gaz toxiques ou de l'oxygène.
  • OLCT 100 XP IR Version antidéflagrante et équipée d'un capteur infrarouge pour la détection des gaz explosibles ou du CO2.
  • OLCT 100 XP HT Version antidéflagrante haute température pour la détection des gaz explosifs jusqu'à 200 °C environ.

 

Télécharger la fiche du produit


XCD

ATEX monitor with indication of the measuring value, 4-20 mA output, 3 alarm relays and MODBUS. Provides comprehensive monitoring of flammable, toxic, and Oxygen gas hazards (catalytic or infrared), CO, CO2, H2, H2S or O2

  • Provided with a tri-color backlit LCD that clearly indicates the unit’s status at a glance
  • 3 alarm relays : 2 programmable gas alarms and one fault alarm
  • 4-20 mA output and MODBUS communication
  • Epoxy painted aluminium alloy LM25 or stainless steel
  • Humidity : 0-99 RH
  • ATEX certification and IP 67 protection
Further information on the fixed detector XCD

La gamme de détecteurs Sensepoint XCD offre des solutions de détection complète des dangers liés aux gaz inflammables, aux gaz toxiques et à l’oxygène dans des atmosphères potentiellement explosives, à l’intérieur comme à l’extérieur. Il est possible de modifier le mode de fonctionnement de chaque détecteur à l’aide de l’écran LCD et de commutateurs magnétiques, sans même qu’il ne soit nécessaire d’ouvrir l’appareil.

Un écran LCD rétro éclairé tricolore indique clairement et immédiatement l’état de l’appareil, même lorsque celui-ci est éloigné. Un rétro éclairage vert permanent indique que le détecteur fonctionne normalement. Si le rétro éclairage est jaune clignotant, il indique une erreur et s’il est rouge clignotant, une condition d’alarme.

Tous les détecteurs sont fournis pré-configurés et comportent 2 relais d’alarme programmables, 1 relais d’erreur programmable, ainsi qu’une sortie standard de 4 à 20 mA (sortie puits ou source sélectionnable) et une sortie MODBUS*.

 

Télécharger la fiche du produit


TVOC

TVOC is a fixed photoionization detector (PID) for the continuous measurement of total volatile organic compounds (VOCs).

  • 10.6 eV lamp able to detect most VOCs
  • Ranges of measure: 0 to 10, 0 to 100, 0 to 1000 ppm
  • Fast response time : T90 < 5 seconds
  • Humidity and heat resistant
  • Large LCD display for clear readings
  • Power supply : 8-28 Vcc, Max 65 mA
Further information on the stationary gas detector TVOC

Le TVOC est un détecteur à photoionisation (PID) stationnaire pour des relevés en continu de composés organiques volatils (COV). Le TVOC relève avec précision sur plus de trois plages de détection, depuis un seul instrument. Le cycle de service variable du TVOC est réglé sur 1 minute en série. L’utilisateur peut l’ajuster pour le régler entre 5 secondes et 5 minutes.

 

Le TVOC utilise une technique diffuse de levée d’échantillons, minimisant les problèmes de contamination comparés aux systèmes pompés, réduisant aussi le nettoyage et l’entretien de la lampe.

 

Grâce à une sortie analogique de 4 à 20 mA, le détecteur fixe COV TVOC peut être simplement installé sur un système de contrôle DCS, afin d’avertir et de contrôler les niveaux élevés de COV sur le lieu de travail. Les agréments ATEX permettent à un système TVOC à 3 fils, d’être utilisé dans les zones dangereuses de catégorie Deux, sans barrières de sécurité.

 

  • Lampe 10,6 eV pour les COV avec un pouvoir IP < 10,6 eV
  • Plage : 0 à 10, à 100, ou à 1 000 ppm sur un seul instrument
  • Résistance à l’humidité sans qu’il soit nécessaire de compenser
  • Des résultats précis sous toute condition atmosphérique
  • Sa conception robuste et solide résiste aux milieux difficiles
  • Grand écran LCD pour des indications claires
  • Simple à utiliser - formation minimale requise

 

Utilisation préconisée : industries cosmétiques, chimiques, pétrochimiques, pharmaceutiques, du papier et des pulpes, peintures industrielles et encres d'imprimerie, revêtements, usines de traitement d’eaux usées, etc ...

 

Télécharger la fiche du produit


OPTIMA PLUS

This material is a fixed detector able to monitor flammable and explosive gases. Its infrared technology permits a great precision and a longer shelf life

  • 50 available spectra to detect explosive gases
  • Dual beam infrared technology, works in inert medium
  • 4 – 20 mA output and optional Multidrop Modbus RS485 (power supply 18-32 Vdc)
  • Outbox: 316 stainless steel and IP 66 / 67 protection
  • Response time : T90 <6.5 seconds
Further information on the fixed detector OPTIMA PLUS

Particulièrement adapté dans les plates-formes pétrolières et gazières, navires de stockage, raffineries, stations de compression et sites d'impression et de revêtements à base de solvants, l'Optima Plus est un détecteur gaz à double faisceau infrarouge d'une très grande longévité et totalement insensible aux poisons catalytiques.

 

Pourquoi l'infrarouge ?

 

  • Fonctionnement à sécurité intrinsèque
  • Temps de réponse rapide
  • Maintenance de routine réduite
  • Immunité contre les poisons catalytiques
  • Très longue durée de vie
  • Fonctionnement possible en atmosphères inertes

 

Les principaux avantages du détecteur gaz inflammable Optima Plus

 

  • Détection de nombreux gaz hydrocarbures y compris des solvants (près de 100 courbes d'étalonnage)
  • Grande stabilité de la mesure
  • Autocompensation optique pour une plus
  • Protection contre les variations à long terme

 

Télécharger la fiche du produit